Critical Buckling Design Value for Compression Member in Major Axis, FcEx
FcEx |
Critical buckling design value for the compression member in the major axis, psi |
Emin' |
= Emin ⋅ CM ⋅ CT ⋅ Ci = 510,000 psi |
le1 |
Effective length = 36.0 in |
d1 |
Member depth = 3.5 in |