69x
001239
18.01.2024

Résistance en traction de la connexion de contreventement requise (OCBF & SCBF)

Required Brace Connection Tensile Strength (OCBF & SCBF)

Ry·Fy·Ag/αs

Ry

Ratio of expected yield stress to the specified minimum yield stress

Fy

Specified minimum yield stress

Ag

Gross area of brace

αs

LRFD-ASD force level adjustment factor = 1.0 for LRFD and 1.5 for ASD


;