FAQ 002099 FR

Modeling | Structure RFEM 5.xx

How can I consider the slip of a cross-laminated timber plate in a wall-liked load?


The slip of a timber wall is computed by using the slip modulus. For a 4 mm nail in a common C24 timber, we obtain a slip of 793.981 N/mm per shear plane. Now, all that is left to do is to consider the mean value of the stiffness and the partial safety factor, which is omitted in this example. The distance of the used nails then gives the necessary longitudinal stiffness of the joint.


joint, nail, slippage



Avez-vous trouvé des réponses à vos questions?

Si non, contactez-nous ou envoyez-nous votre question via le formulaire.

+33 1 78 42 91 61


Premiers Pas

Premiers pas

Ici vous trouverez quelques trucs et astuces pour faciliter votre prise en main des logiciels de calcul de structure RFEM et RSTAB.