FAQ 000459 FR

Calcul RF-STEEL

Are warping stresses in structural components (for example, an I-section cantilever) that are subject to torsion considered in the add-on module STEEL?

Réponse

No, warping stresses are not considered in such structural components.

In RSTAB or STEEL, warping torsion is of no importance, and the warping resistance has no influence.

The STEEL module calculates the torsional stresses using MT/WT or MT/(IT/z), which of course represents an approximation and cannot be compared with the warping torsion.

In the moment, warping is considered only in the modules FE-LTB and SHAPE-THIN.

Contactez-nous

Contactez-nous

Avez-vous trouvé des réponses à vos questions?

Si non, contactez-nous ou envoyez-nous votre question via le formulaire.

+33 1 78 42 91 61

info@dlubal.fr

RFEM Structures en acier
RF-STEEL 5.xx

Module additionnel

Analyses de contraintes des barres et des surfaces