Add-on modules CONCRETE RF-CONCRETE 8.xx 5.xx

How can I deactive individual internal forces for design in CONCRETE or RF-CONCRETE Members (for example torsional moment M-T for ribs)?

Réponse

The internal forces to be considered in design can be found in the "1.6 Reinforcement" window, "Reinforcement Layout" tab. Here you can select the internal forces, which should not be taken into account for the respective reinforcement group. Please note that this setting is valid for all members of the reinforcement group. You should use this function carefully.