This structural analysis model available for download may be used for learning or testing purposes. There is no guarantee or liability for the accuracy or completeness of the model.
Verification Example 1022 | Slab Designed According to DIN EN 1992-1-1 with NA
Model to Download
Description
Verification Example 1022 | Slab Designed According to DIN EN 1992-1-1 with NA
Model Used in
Write Comment...
Write Comment...
- Views 362x
- Downloads 5x
- Updated 03/19/2023
- Number of Nodes 125
- Number of Lines 104
- Number of Members 0
- Number of Surfaces 26
- Number of Solids 0
- Number of Load Cases 3
- Number of Load Combinations 1
- Number of Result Combinations 0
- Total Weight 452.102 tons
- Dimensions 90.06 x 0 x 90.06 feet
Disclaimer

Adjusting Reinforcement Drawings