FAQ 004246 | I want to design a crack width of 0.1 mm in RF‑CONCRETE Surfaces. But when entering "0.10 mm" as the limit value, I get an error message saying that a value between 0.2 to 0.4 mm can only be designed.

Easily learn how to work with the Dlubal Software programs

  • Dlubal Software | Videos

Video

First Steps with RFEM

First steps

We provide hints and tips to help you get started with the basic program RFEM.

11/26/2019

001042

Paul Kieloch

Please accept Marketing Cookies to watch this video.

Question

I want to design a crack width of 0.1 mm in RF‑CONCRETE Surfaces. But when entering "0.10 mm" as the limit value, I get an error message saying that a value between 0.2 to 0.4 mm can only be designed.

Answer

Please deactivate the "indirect calculation" using the limit diameter "lim ds" or the member spacing "lim sl."

The calculation of crack widths smaller than 0.20 mm is only possible by using the direct calculation according to EN 1992‑1‑1, 7.3.4.