FAQ 004946 EN-US
Is it possible to make the generated member loads from area loads via plane to act eccentrically on the member cross-section?
Answer
Yes, this is possible in RFEM. However, you have to disconnect the generated load first. The generated loads are then converted into normal member loads and can be changed as required.
Image 01 - Disconnect Generated Load
After disconnecting the generated loads, you can define the load eccentricity.
Image 02 - Defining Load Eccentricity
As expected, the member loads generate a torsional moment if they act eccentrically to the shear center.
Image 03 - Comparison - Torsional Moment
The options for RSTAB are described in FAQ 2361.
Keywords
Member load eccentric Load eccentricity Generated load
Downloads
Contact us
Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.
Recommended Events
Timber Beam and Surface Structures | Part 1: Modeling, Load Input, Combinatorics
Webinar 05/04/2021 2:00 PM - 3:00 PM CEST
Eurocode 3 | Steel structures according to DIN EN 1993-1-1
Online Training 05/06/2021 8:30 AM - 12:30 PM CEST
Eurocode 2 | Concrete structures according to DIN EN 1992-1-1
Online Training 05/12/2021 8:30 AM - 12:30 PM CEST
Eurocode 5 | Timber structures according to DIN EN 1995-1-1
Online Training 05/20/2021 8:30 AM - 12:30 PM CEST
RFEM | Structural dynamics and earthquake design according to EC 8
Online Training 06/02/2021 8:30 AM - 12:30 PM CEST
Videos
Models to Download
Knowledge Base Articles

New
To simulate a bearing clearance in a connection between members, you can use the Diagram function for member end releases.Screenshots
RFEM/RSTAB Add-on Module RF-IMP/RSIMP | Generation of Geometric Replacement Imperfections and Pre-deformed Replacement Structures
Designed with the FEA Software RFEM 3 | I am constantly impressed by the range of its capabilities/flexibilities that Dlubal offers | Design Manager Hünnebeck
FEA Software RFEM & Structural Analysis Software RSTAB | Video Tutorial | Creating and Importing Blocks
Product Features Articles

New
Depending on stiffness, mass, and damping, structures react differently to wind action.
Frequently Asked Questions (FAQ)
- How is it possible to add or remove tables in the printout report?
- The display of result values is too inaccurate. Where can I set to see more result values for member internal forces?
- How do I apply prestress to tension members?
- I have numeric stiffnesses of my members. How can I assign the stiffnesses to a member without having to create a notional material and a cross-section?
- I have bought a new computer. How can I use my softlock license on it?
- How do I install the network license (USB dongle) on the server?
-
In my Dlubal Software programs, I have a problem that the umlauts and special characters cannot be displayed. How can I change that?
- Can I also use the load generator for the members that do not rest in one plane?
- How is the friction set on a member hinge via the COM interface?
- Is it possible to keep the results from RWIND Simulation when deleting the FE mesh if I only adjust materials or support conditions?
Customer Projects
Associated Products