When performing the fire resistance design with TIMBER Pro, I get the error 10001. How can I fix the error?

Answer

If this error message is displayed, the cross -section is obviously not sufficient because there is no remaining cross -section after the specified fire resistance period. You can check this very easily by reducing the fire resistance time in the detail settings until the design is just possible.



In the result of the fire protection design, you can see very well in the graphic how much residual cross -section is still available after the set fire duration.

Keywords

Fire Resistance Fire resistance residual cross-section Error 10001 Structural fire design