11x
001038
2024-01-16

Rear Wall Scaled Distance

Scaled distance calculation for the blast explosion on the front facing wall
Z = RW3 = 120 ft500 lb3 = 15.1 ftlb1/3
R Distance from the element to charge
W TNT equivalent charge weight