484x
005462
2024-03-12

Load Transfer Surfaces

The loads from the load transfer surfaces are not displayed. Where are they?


Answer:

First, it is worth taking a look at the "Load Transfer" tab when editing the surface. If the load transfer direction is set to "Isotropic | FEM", the loads are not displayed until the load case or load combination has been calculated, as they must be calculated in a sub-model first. So make sure the results are available there.


Author

Gerhard works in product engineering in the field of timber structures and also assists with customer support. He draws on his development experience to create practical and actionable solutions.



;