Designing Bucket Footing

Tips & Tricks

In the RF‑/JOINTS Steel - Column Base add‑on module, we have implemented the option for designing bucket footings at the restrained column bases.

The following checks are possible:

  • Check of the required restraining depth
  • Elastic cross‑section design of the column base section
  • Design of the concrete bearing capacity below the base plate
  • Design of the weld seams