RX-TIMBER Purlin | Features

Product Feature

  • Design of the following geometry types:
    • Single-span beam with and without cantilever
    • Continuous beam with and without cantilever
    • Hinged girder system (Gerber) with and without cantilever
  • Automatic generation of wind and snow loads
  • Automatic creation of required combinations for the ultimate and serviceability limit state as well as fire resistance design
  • In EC 5 (EN 1995), the following National Annexes are currently available:
    • United Kingdom BS EN 1995-1-1/NA:2009-10 (United Kingdom)
    •  ÖNORM B 1995-1-1:2015-06 (Austria)
    • Belgium NBN EN 1995-1-1/ANB:2012-07 (Belgium) 
    •  CSN EN 1995-1-1:2009-07 (Czech Republic)
    •  DK EN 1995-1-1/NA:2011-12 (Denmark)
    •  SFS EN 1995-1-1/NA:2007-11 (Finland)
    •  NF EN 1995-1-1/NA:2010-05 (France)
    •  DIN EN 1995-1-1/NA:2013-08 (Germany)
    •  UNI EN 1995-1-1/NA:2010-09 (Italy)
    •  NEN EN 1995-1-1/NB:2007-11 (Netherlands)
    •  PN EN 1995-1-1/NA:2010-09 (Poland)
    •  STN EN 1995-1-1/NA:2008-12 (Slovakia)
    •  SIST EN 1995-1-1/A101:2006-03 (Slovenia)
    •  SS EN 1995-1-1 (Sweden)
  • Consideration of optimization options by user-specifications according to the respective standard:
    • Shear force reduction of single loads near support
    • Shear force reduction of load introduction at the cross-section top point
    • Moment redistribution in support zone
    • Reduction of torsional stress by means of user-defined entry of moment
    • Increase of bending stiffnesses for flat-ended or edgewise bending strains
  • Simple geometry input with illustrative graphics
  • Extensive material library for both standards
  • Optional extension of material library by further materials
  • Extensive library of permanent loads
  • Allocation of framework to service classes and specification of service class categories
  • Determination of design ratios, support forces and deformations
  • Info icon indicating successful or failed design
  • Color reference scales in result tables
  • Direct data export to MS Excel
  • Program languages: English, German, Czech, Italian, Spanish, French, Portuguese, Polish, and Russian
  • Verifiable printout report with all required designs available in many languages, for example English, German, French, Italian, Spanish, Russian, Czech, Polish, Portuguese, Dutch
  • Direct import of stp files from various CAD programs

Contact us

Contact Dlubal Software

Do you have any questions or need advice?
Contact us via e-mail, chat or forum. Find also various suggested solutions and useful tips on our FAQ page.

(267) 702-2815

info-us@dlubal.com

Stand-Alone Timber Structures
RX-TIMBER Purlin 2.xx

Stand-Alone Program

Timber design of coupled purlins and continuous beams according to Eurocode 5 or DIN 1052

Price of First License
360.00 USD