The verification example compares wind load calculation of a duopitch roof building utilizing the standard EN 1991-1-4 and the CFD simulation in RWIND Simulation. The building is defined according to the sketch and the inflow velocity profile is taken according to the standard EN 1991-1-4.


(0)
0 out of 5 stars
5 star 0
4 star 0
3 star 0
2 star 0
1 star 0

Verification Example 000302 | 2

Number of Nodes 10
Number of Lines 17
Number of Surfaces 10
Number of Solids 2
Number of Load Cases 1
Total Weight 2413.125 tons
Dimensions (Metric) 10.000 x 13.500 x 8.300 m
Dimensions (Imperial) 32.81 x 44.29 x 27.23 feet
Program Version 5.22.00