This model represents a bolted column splice connecting different cross-sections using an L-section and a splice plate. The connection is designed with staggered bolt spacing to optimize load transfer. It is suitable for use in RFEM or RSTAB to analyze the structural behavior of the splice detail.
Column Splice with Splice Plates
| Number of Nodes | 3 |
| Number of Lines | 2 |
| Number of Members | 2 |
| Number of Surfaces | 0 |
| Number of Solids | 0 |
| Number of Load Cases | 4 |
| Number of Load Combinations | 8 |
| Number of Result Combinations | 0 |
| Total Weight | 0.068 tons |
| Dimensions (Metric) | 0.000 x 2.000 x 0.000 m |
| Dimensions (Imperial) | 0 x 6.56 x 0 feet |
You can download this structural model to use it for training purposes or for your projects. However, we do not assume any guarantee or liability for the accuracy or completeness of the model.