RFEM model of a temporary, covered grandstand structure for analyzing its structural behavior under event loads. The structure combines a steel frame structure with a membrane or foil roof and is suitable for analyzing wind, snow, and dead-load effects. The model serves as a basis for the design of temporary spectator grandstands, with a focus on stability and deformation behavior. It takes into account the relevant loads in accordance with applicable standards for temporary structures.
Temporarily Covered Grandstand
| Number of Nodes | 4286 |
| Number of Lines | 8456 |
| Number of Members | 8326 |
| Number of Surfaces | 0 |
| Number of Solids | 0 |
| Number of Load Cases | 6 |
| Number of Load Combinations | 20 |
| Number of Result Combinations | 2 |
| Total Weight | 23.256 t |
| Dimensions (Metric) | 77.500 x 7.150 x 12.000 m |
| Dimensions (Imperial) | 254.27 x 23.46 x 39.37 feet |