High-Bay Warehouse in Brittany, France

This logistics project combines two buildings with complementary functions: a very tall warehouse, the HIGH BAY, and an adjoining loading building, the LOW BAY. Both structures are built with a precast concrete frame. What sets this project apart is the height of the HIGH BAY: whereas a typical logistics building reaches a height of about 10 meters, this one reaches 37.75 meters at the parapet. This extraordinary height determined the entire design process, from the configuration of the columns to the modeling of the foundations. Both buildings were analyzed using RSTAB.

Design

The HIGH BAY is a warehouse consisting of two high-ceilinged bays. Its structure is based on a system of precast concrete columns, beams, and purlins. Given the required height of 37.75 m (123.85 ft), the columns were constructed in two sections, joined together using Peikko connections. For the facade columns, the upper section was cast in a single pour and consists of two different sections, which allows for the adjustment of the moment of inertia to respond to varying loadings along the height while maintaining a single precast element.

The LOW BAY is also constructed using a precast concrete frame. It features a floor system consisting of beams combined with prestressed hollow-core slabs (DAP) across its entire surface. The overall stability of the building was analyzed using RSTAB.

The analyses were conducted for both the service phase and the temporary phase, the latter being critical for a structure of this height, where the erection configurations load the elements significantly before the permanent bracing is installed.

Required Analysis Tools

All analyses, for both buildings as well as the service and temporary phases, were performed in RSTAB.

One modeling aspect warrants special mention: rather than assuming perfectly fixed columns at their bases, a non-infinite stiffness was introduced to account for the actual rotation of the foundations. In a building with a height of almost 38 m (125 ft), this flexibility significantly alters both the distribution of moments at the base and the displacements at the top; neglecting this flexibility would result in a design that does not accurately reflect the actual structural behavior.

Engineering Office's Responsibility

The scope of work included the transfer of loads to the bases of concrete columns, the design calculations for the columns, beams, and purlins, as well as the modeling of a 3D model used to produce the construction drawings and fabrication specifications for the structural members (columns, beams, purlins).

General Contractor
Concrete Carpenter
Concrete Structural Engineer


Project Specifications

Model Data

Number of Nodes 776
Number of Lines 996
Number of Members 996
Number of Surfaces 0
Number of Solids 0
Number of Load Cases 21
Number of Load Combinations 35
Number of Result Combinations 0
Total Weight 9841.339 t
Dimensions (Metric) 118.520 x 38.250 x 68.750 m
Dimensions (Imperial) 388.85 x 125.49 x 225.56 feet