Wieland Götzler Add-on Modules STEEL EC3 RF-STEEL EC3

The proof of stability in STEEL EC3 is exceeded. What can I do?

Answer

You can change the profile, generally adapt the model and its loads, or enable stabilization in STEEL EC3.
In particular, the settings for latitudinal bedding and shear field in the mask 1.12 Bar parameters or 1.13 Bar set parameters, which are then taken into account in the module-internal eigenvalue solver for determining the branch load, are suitable for this purpose.

Keywords

Steel construction Stability Stability analysis Stabilization Rotational bedding Thrust field Eurocode 3 EC3 Eigenvalue solver