Results of Fire Resistance Design

I get no results for fire resistance design in the Steel Design add-on. Instead, I get a warning message. Why?


Answer:

The most important requirement for performing fire resistance design is to select the check box for fire resistance in the Global Settings for Steel Design.

After activating the setting, an entry for the fire resistance configuration appears in the “Data” Navigator under the “Steel Design” folder.