Maximum Peak Overpressure of Remote Explosion (Kinney & Graham)

Formula

Customer Support 24/7

Knowledge Base

In addition to our technical support (e.g. via email, chat), we also offer an extensive range of free online services available 24/7 on our website.

000875

Based on various tests. Formula for calculating the peak overpressure. The maximum peak overpressure is specified as a function of the scaled distance Z.

p^10 = p0 · 808 · 1 + Z4,521 + Z4,52 · 1 + Z0,322 · 1 + Z1,352

p10 Maximum peak pressure of remote explosion (Kinney & Graham) [kPa]
p0 Atmospheric pressure under normal conditions (101.3 [kPa])
Z Scaled distance [m/kg1/3]

Maximum Peak Overpressure of Remote Explosion (Kinney & Graham)