54x
001030
2024-01-16

Adjusted Minor Axis Bending Design Value, Fby'

Adjusted Minor Axis Bending Design Value, Fby'
Fby' = Fb2 = Fb · CD · CM · CL · Ct · Cfu · CF · Ci · Cr
Fby' = Fb2 = 1,100 psi · 1.6 · 1.0 · 1.0 · 1.0 · 1.1 · 1.0 · 1.0 · 1.0
Fby' = Fb2 = 1,936 psi
Fby' Adjusted minor axis bending design value, psi
Fb Reference bending design value, psi
CD Load duration factor
CM Wet service factor
CL Beam stability factor
Ct Temperature factor
Cfu Flat use factor
CF Size factor
Ci Incising factor
Cr Repetitive member factor


;