984x
001021
2015-05-05

Deactivation of Individual Dowels in RF-/JOINTS Timber - Steel to Timber

In RF‑/JOINTS Timber, you can remove an individual dowel from the calculation, thus creating any dowel layout. The calculation disregards these removed dowels for the ultimate limit state design, as well as for the net timber cross‑section analysis and the rotational spring stiffness determination.

You can find this setting in Window "1.5 Geometry" under "Details - List of Dowels". You can also define the dowel diameters individually here.


Author

Mr. Ackermann is the contact person for sales inquiries.