33x
500295
2025-10-06

Partial Internal Forces Method – Limit l/t

The partial internal forces method without redistribution is designed for thin-walled elements with t≪l. To avoid the calculation of solid elements (for example, with t=l), the default value of the limit value l/t in the Ultimate Configuration was set to 5 according to Kindmann and Frickel (2002), 9.1, Section 9.1.



;