FAQ 002119 FR

Add-on modules FRAME-JOINT Pro RF-FRAME-JOINT Pro 8.xx 5.xx

After the calculation start, RF-/FRAME-JOINT Pro appears in the "1.2 Cross-Sections" window and shows the following error message: "The value is out of the allowed range. Design value: 0.00 - Min. value: 3.00". However, I cannot detect a mistake.

Réponse

Columns consist of a parametrized I-section (welded section). To use such a cross-section in RF-/FRAME-JOINT Pro, it is necessary to enter the web weld thickness as well. On the one hand, the weld in tension area is designed in RF-/FRAME-JOINT Pro; on the other hand, your thickness is also used in the calculation of effective lengths of the T-stub.

Mots-clés

error message. warning, value

Contactez-nous

Contactez-nous

Avez-vous trouvé des réponses à vos questions?

Si non, contactez-nous ou envoyez-nous votre question via le formulaire.

+33 1 78 42 91 61

info@dlubal.fr

Premiers Pas

Premiers pas

Ici vous trouverez quelques trucs et astuces pour faciliter votre prise en main des logiciels de calcul de structure RFEM et RSTAB.