FAQ 002119 FR

Add-on modules FRAME-JOINT Pro RF-FRAME-JOINT Pro 8.xx 5.xx

After the calculation start, RF-/FRAME-JOINT Pro appears in the "1.2 Cross-Sections" window and shows the following error message: "The value is out of the allowed range. Design value: 0.00 - Min. value: 3.00". However, I cannot detect a mistake.

Réponse

Columns consist of a parametrized I-section (welded section). To use such a cross-section in RF-/FRAME-JOINT Pro, it is necessary to enter the web weld thickness as well. On the one hand, the weld in tension area is designed in RF-/FRAME-JOINT Pro; on the other hand, your thickness is also used in the calculation of effective lengths of the T-stub.

Mots-clés

error message. warning, value

Contactez-nous

Contactez-nous

Avez-vous trouvé des réponses à vos questions?

Si non, contactez-nous ou envoyez-nous votre question via le formulaire.

+33 1 78 42 91 61

info@dlubal.fr

Premiers Pas

Premiers pas

Ici vous trouverez quelques trucs et astuces pour faciliter votre prise en main des logiciels de calcul de structure RFEM et RSTAB.

Un excellent service de support technique

« Mes compliments à l’équipe du support technique

J’aimerais vous remercier pour votre aide qui m’a été précieuse. Je suis toujours impressionné par la vitesse et la qualité des réponses fournies à mes questions. Je dispose de plusieurs contrats de service avec des acteurs du domaine du calcul de structure, mais votre support technique est de loin le meilleur. »