I have modelled a precast slab as "orthotropic surface". Can I use these surfaces also in reinforced concrete design?

Odpowiedź

Yes, you can use "orthotropic surfaces" for the reinforced concrete design in RF-CONCRETE Surfaces.

If you only would like to carry out serviceability limit state designs, you do not have to define additional settings in RF-CONCRETE Surfaces concerning the surface type.

You need the RF-CONCRETE NL add-on module to perform the serviceability limit state designs. Select in the "serviceability limit state" tab (in the dialog box "1.1 General Data") the design method "Nonlinear...". See Figure 01.

You can then change the surface type to "Constant" in the dialog box "1.3 Surfaces" so that the serviceability limit state design is also possible here. See Figure 02.

Słowa kluczowe

orthotropy, orthotropic surface, precast slab, precast elements

Kontakt

Kontakt do Dlubal

Jeśli nie znaleźli Państwo odpowiedzi na pytania, mogą Państwo skontaktować się z nami lub wysłać zapytanie za pomocą formularza.

+48 (32) 782 46 26

+48 730 358 225

info@dlubal.pl

RFEM Konstrukcje z betonu zbrojonego
RF-CONCRETE 5.xx

Moduł dodatkowy

Wymiarowanie prętów i powierzchni (płyt, ścian, konstrukcji płaskich, powłok) z betonu zbrojonego

Cena pierwszej licencji
810,00 USD
RFEM Konstrukcje z betonu zbrojonego
RF-CONCRETE NL 5.xx

Moduł dodatkowy

Fizyczna i geometryczna analiza nieliniowa belek i płyt z betonu zbrojonego