695x
000355
2020-01-08

[EN] FAQ 003115 | Why are new members generated in my model when crossing one member with ...

Question:
Why are new members generated in my model when crossing one member with another one?

Answer:
Once the "Auto Connect Members" feature is activated, the member touching the start or end node of another member is divided. If this feature is not activated, this means for the RSTAB model that the members are not connected to each other.

Members that intersect each other (for example, the wind bracing of a hall) are not divided.