The option to increase the material factor ε is greyed out in Details - Ultimate Limit State, why?

Answer

According to EN 1993-1-1, it is only possible to increase the material factor based on the applied stresses if stability analyses are not performed with the equivalent member design. Since equivalent member designs are activated in the next tab 'Stability' by default, this check box is greyed out.

After deactivating the equivalent member design, this checkbox is enabled and activated by default.

Keywords

material factor epsilon Eurocode 3 stability ultimate limit state cross-section classification steel structures EC3 equivalent member design

Contact us

Contact to Dlubal

Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.