681x
002950
2019-04-17

Error "Invalid Loading Due to M-T" in EL-PL

For a design in the EL‑PL add-on module, I get the error "4) Invalid loading due to M‑T"; what can I do?


Answer:

The add-on module performs the calculation according to DIN 18800, where a design with torsional forces is not possible. However, an elastic-plastic design with torsion is possible in the STEEL EC3 add-on module.


Author

Mr. Günthel provides technical support for our customers.



;