Question

For a design in the EL‑PL add-on module, I get the error "4) Invalid loading due to M‑T"; what can I do?


Answer:
The add-on module performs the calculation according to DIN 18800, where a design with torsional forces is not possible. However, an elastic-plastic design with torsion is possible in the STEEL EC3 add-on module.