Correct Display of Incrementally Applied Variable Load Distribution

I have set a variable load distribution for a generated load. This should be applied incrementally in a certain direction. However, the load is not stepped, but is displayed with a linear distribution. How can I display the load correctly?


Answer:

In order to display the loads correctly, it is necessary to make some adjustments. In the case of an incrementally applied load, the boundary of the area load plane may only be defined in sections (by load increment). Otherwise, the load is distributed linearly over the entire area load plane.


Author

Mr. Baumgärtel provides technical support for Dlubal Software customers.