Thus, the stiffnesses of both members are taken into account in the calculation, and member eccentricities can also be used. This can be useful, for example, when defining composite cross-sections.

As with the modeling of a composite cross-section using coupling members, it is important to ensure that the composite beam is divided into a sufficient number of members.


Author

Mr. Hoffmann is responsible for development in the areas of dynamic analysis, membrane structures, and RWIND. Furthermore, he provides technical support for our customers.