1215x
004294
2020-01-14

Question

Does the software RWIND Simulation account for the internal pressure coefficient (GCpi) from the ASCE 7‑16?


Answer:
The internal pressure coefficients do not need to be considered in the RWIND Simulation program. 

RWIND Simulation always outputs the net pressure on the surfaces in RFEM. When it comes to a simulation with a building that has open windows in RWIND Simulation, there is an internal pressure acting on the inside of the building. The program uses this information to determine the resulting pressure based on the external and internal surfaces. This can be seen in Image 01.


A comparison cannot be made between this coefficient in the standard and a CFD calculation because there is no direct correlation. 

Author

Alex is responsible for customer training, technical support, and continued program development for the North American market.

Links
References
  1. ASCE/SEI 7‑16, Minimum Design Loads and Associated Criteria for Buildings and Other Structures