658x
26x
000290
2019-12-23

The verification example compares wind load calculation of a duopitch roof building utilizing the standard EN 1991-1-4 and the CFD simulation in RWIND Simulation. The building is defined according to the sketch and the inflow velocity profile is taken according to the standard EN 1991-1-4.


(0)
0 out of 5 stars
5 star 0
4 star 0
3 star 0
2 star 0
1 star 0

Verification Example 000302 | 1

Number of Nodes 10
Number of Lines 17
Number of Surfaces 10
Number of Solids 2
Number of Load Cases 2
Total Weight 2413.125 tons
Dimensions (Metric) 10.000 x 13.500 x 8.300 m
Dimensions (Imperial) 32.81 x 44.29 x 27.23 feet
Program Version 5.22.00

You can download this structural model to use it for training purposes or for your projects. However, we do not assume any guarantee or liability for the accuracy or completeness of the model.

Report This 3D Model