Hotel at Rotterdam Airport, the Netherlands
Customer Project
The Landslide Hotel is located near Rotterdam Airport. The multi-story reinforced concrete structure was designed by the engineering office of Van Numen from Rosmalen, the Netherlands, and the structural analysis was performed utilizing RFEM.
Architecture and Structural Design |
Raadgevend Ingenieursburo van Nunen B.V., the Netherlands www.nunen.com |
Write Comment...
Write Comment...
Contact Us
Do you have any further questions or need advice? Contact us via phone, email, chat or forum or find suggested solutions and useful tips on our FAQ page, available 24/7.

Failing Support Conditions for Contact Surfaces
In order to create a surface model with failing supports close to reality, an option called "Failure if contact perpendicular to surfaces failed" is available in RFEM 5 for contact solids under "Contact Parallel to Surfaces".

Increased Calculation Performance by Reducing the Nodal Degrees of Freedom
The number of degrees of freedom in a node is no longer a global calculation parameter in RFEM (6 degrees of freedom for each mesh node in 3D models, 7 degrees of freedom for the warping torsion analysis). Thus, each node is generally considered with a different number of degrees of freedom, which leads to a variable number of equations in the calculation.
This modification speeds up the calculation, especially for models where a significant reduction of the system could be achieved (e.g. trusses and membrane structures).
-
Is it possible to change the properties of members or surfaces in the individual construction stages, such as their location?
- I am trying to import a DXF file. The file can be imported into the model, but it does not have the correct scale. Where is the problem?
- Is it possible to apply a factor to the loads of one or more load cases that uniformly increases or decreases all loads in these load cases?
- When exporting to Excel, I get the error message "Microsoft Excel is not installed on this computer" although Excel is installed. Why?
- Is the German National Annex 2021‑07 to Eurocode 8 available in RFEM 5 / RSTAB 8?
-
How can I permanently save the parameters in the "Units and Decimal Places" dialog box?
- Can I export a response spectrum from RFEM 6 and use it in RFEM 5, for example?
- I have deactivated objects by load case. Why are they still considered in the calculation in the corresponding load case?
- I would like to enter a large spring constant. Is it possible?
- What is the maximum number of reinforcement groups that can be created in a design case in RF‑CONCRETE Surfaces?
- I am trying to import a DXF file. The file can be imported into the model, but it does not have the correct scale. Where is the problem?