Is it possible to design insulating glass with the RF-GLASS add-on module?

Answer

Yes, you can define the required glass pane structure in tab 1.2 Layers. To be able to define insulated glass, you have to assign at least one glass layer to the structure. Then, you receive the additional option for the gas layer.
After defining the gas layer, you receive additional tabs where you can enter more specific data for the design.

Keywords

IGU Insulating glass Multiple panels insulated glass Glass structure

Contact us

Contact to Dlubal

Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.