Question

How is the position of the additional reinforcement considered in RF‑CONCRETE Surfaces when determining hc,ef?


Answer:
If the position of the additional reinforcement is different from the position of the basic reinforcement, a common weighted centroidal axis is determined. This in turn has an influence on the SLS design (for example, Ac,eff).