Using the example of an axially compressed reinforced concrete column, this article shows how slenderness, limiting slenderness, cross-section depth, and longitudinal reinforcement are determined by hand according to EN 1992-1-1 and how the same results are obtained with the Concrete Design add-on in RFEM 6.
What is axial compression?
Axial compression occurs when all forces on one side of the cross-section can be combined into a single axial force N at the center of gravity. In practice, this case hardly ever occurs: load asymmetries and execution inaccuracies always create small eccentricities. EN 1992-1-1 takes this into account with the minimum eccentricity e0 according to 6.1(4), which RFEM 6 applies by default (see calculation procedure 1).
Slenderness criterion for individual compression members
Second-order effects may be neglected if the slenderness is below the limiting slenderness (EN 1992-1-1, 5.8.3.1):
λ < λlim
Slenderness and effective length
Slenderness and effective length according to 5.8.3.2 and equation (5.15) for braced members:
λ = l0 / i l0 = kcr · l kcr = 0.5 · √((1 + k1 / (0.45 + k1)) · (1 + k2 / (0.45 + k2)))
Here, i is the radius of gyration of the uncracked reinforced concrete cross-section, l is the free length, and k1, k2 are the relative flexibilities of the end restraints.
Limiting slenderness
Limiting slenderness according to equation (5.13N):
λlim = λ0,lim · A · B · C / √n with λ0,lim = 20 A = 1 / (1 + 0.2 · φef) B = √(1 + 2 · ω) C = 1.7 − rm n = NEd / (Ac · fcd)
If φef, ω, or rm are unknown, the recommended values A = 0.7, B = 1.1, and C = 0.7 apply. The pre-factor λ0,lim = 20 is stored in RFEM 6 as a standard parameter of the ultimate configuration. The mechanical reinforcement ratio is ω = As · fyd / (Ac · fcd).
Stresses in steel and concrete
Under axial compression, the concrete compressive strain is limited to εc2 (parabola-rectangle diagram). Due to the composite action, the reinforcement undergoes the same strain:
σs = fyd, if εc2 ≥ εyd σs = Es · εc2, otherwise εyd = fyd / Es fyd = fyk / γs fcd = αcc · fck / γc
Required reinforced concrete cross-section
From the equilibrium of the concrete force Fc = Ac · fcd and the steel force Fs = NEd − Fc, with an assumed reinforcement ratio As / Ac:
Ac ≥ NEd / (fcd + As / Ac · σs) As = (NEd − Ac · fcd) / σs
Example and manual calculation
Required are the depth h ≥ b and the longitudinal reinforcement of a column with a fixed width b = 40 cm. Result: h = 45 cm with 4 Ø 20 (As = 12.57 cm2); the required area is 9.41 cm2.
| Parameter | Value |
| Permanent load Ng (LC 1) | 1,390 kN |
| Variable load Nq (LC 2) | 1,000 kN |
| Column length l | 2.10 m |
| Cross-section | Rectangle b = 40 cm, h ≥ 40 cm required |
| Self-weight of the column | neglected |
| Concrete | C25/30 |
| Reinforcing steel | B500S(A) |
| Longitudinal reinforcement / stirrup | Ø 20 / Ø 8 |
| Concrete cover cnom | 30 mm |
Material properties
fcd = 1.0 · 25 N/mm2 / 1.5 = 16.67 N/mm2 fyd = 500 N/mm2 / 1.15 = 435 N/mm2 εyd = 435 N/mm2 / 200,000 N/mm2 = 2.17 ‰
Since εc2 = 2.0 ‰ < εyd = 2.17 ‰, the steel does not yield: σs = 200,000 N/mm2 · 0.002 = 400 N/mm2
Design load (ULS)
NEd = 1.35 · 1,390 kN + 1.50 · 1,000 kN = 3,376.5 kN
Effective length and slenderness
In the model, the column is restrained at the base and free at the top so that the load can be applied. In reality, the top connects to beams that are stiffer than the column; therefore, restraint is assumed on both sides. Instead of the ideal flexibility of 0, the commonly used minimum value k1 = k2 = 0.1 is applied:
kcr = 0.5 · (1 + 0.1 / (0.45 + 0.1)) = 0.59 λz = 0.59 · 2.10 m · √12 / 0.40 m = 10.73 [-]
The smaller dimension b is governing, since h > b is assumed.
Preliminary check with h = b = 40 cm
n = 3.3765 MN / ((0.40 m)2 · 16.7 MN/m2) = 1.26 [-] λlim = 20 · 0.7 · 1.1 · 0.7 / √1.26 = 9.6 < λz = 10.73
The criterion is just barely not met. Since the actual depth will be larger, the calculation continues axially and the final design is performed with the selected depth.
Required depth (assumption As / Ac = 1%)
Ac ≥ 3.3765 MN / (16.7 MN/m2 + 400 MN/m2 / 100) = 0.163 m2 h ≥ 0.163 m2 / 0.40 m = 0.41 m → h = 45 cm
Required reinforcement
Fc = 0.40 m · 0.45 m · 16.67 MN/m2 = 3.00 MN Fs = 3.3765 MN − 3.00 MN = 0.3765 MN As,req = 0.3765 MN / 400 MN/m2 · 104 = 9.41 cm2
Selected: 4 Ø 20 in the corners, As,prov = 12.57 cm2. The design rules according to 9.5.2 are met: As,min = 0.10 · NEd / fyd = 0.10 · 3,376.5 kN / 43.5 kN/cm2 = 7.8 cm2 ≤ 12.57 cm2 ≤ As,max = 0.04 · Ac = 72 cm2
Limiting slenderness with h = 45 cm
ω = 12.57 cm2 · 435 N/mm2 / (40 cm · 45 cm · 16.7 N/mm2) = 0.182 [-] B = √(1 + 2 · 0.182) = 1.17 [-] n = 3.3765 MN / (0.40 m · 0.45 m · 16.7 MN/m2) = 1.125 [-] λlim = 20 · 0.7 · 1.17 · 0.7 / √1.125 = 10.81 > λz = 10.73
The slenderness criterion is met; second-order effects may be neglected. Note: With the unrounded kcr = 0.591 and B = 1.168, this results in λz = 10.75 and λlim = 10.79 – the difference is very small, so the result remains the same.
Model in RFEM 6
The column is modeled as a member with a length of 2.10 m, fully restrained at the base and loaded at the top with two nodal loads: 1,390 kN in the load case "Self-weight" and 1,000 kN in the load case "Imposed load". The self-weight of the column remains neglected, as in the manual calculation.
For the design situation ULS (STR/GEO), the load combination LC 1 = 1.35 · LC 1 + 1.50 · LC 2 is created with NEd = −3,376.5 kN.
Concrete C25/30 and reinforcing steel B500S(A) are taken from the material library. RFEM 6 displays the values governing the design in the design check details: the ultimate strain εc2 = −2.0 ‰ in the chapter "Material properties → Concrete properties → Strains", fcd = 16.67 N/mm2 and fyd = 434.8 N/mm2 in the chapter "Limiting slenderness according to 5.8.3.1(1)". A parametric rectangle 400/450 mm is used as the cross-section.
The provided reinforcement is defined directly on the member: in the "Longitudinal reinforcement" tab, 4 Ø 20 in the corners (reinforcement bar type "Symmetric" with 2 bars per side), in the "Concrete cover" tab, 30 mm, and in the "Shear reinforcement" tab, stirrups Ø 8.
So that RFEM 6 can perform the stability analysis, the member is additionally assigned an effective length with ky = kz = 0.59 and the structural type "Non-sway" in both directions, matching equation (5.15) for braced members.
All further settings are found in the ultimate configuration. Depending on the objective, the design is carried out in one of two calculation procedures: calculation procedure 1 verifies the slenderness and designs according to the standard with minimum eccentricity, while calculation procedure 2 replicates the pure axial compression of the manual calculation. The model for download contains the settings of calculation procedure 1.
Calculation procedure 1 – Verifying slenderness
In calculation procedure 1, the equivalent member method remains activated. RFEM 6 verifies λz = 10.73 < λlim = 10.81; second-order effects are omitted. At the same time, this is the design according to the standard with minimum eccentricity – with 4 Ø 20, the utilization is 1.11.
| Setting | Value | Location in RFEM 6 |
| Effective length factors | ky = kz = 0.59 | Concrete Design → Effective lengths, assigned to the member |
| Perform stability analysis with equivalent member method | Activated (default) | Ultimate configuration |
| Factor A | 0.7 user-defined (default: determined from φef, here 1.0) | Ultimate configuration, tab "Stability → Slenderness", y and z |
| Factor B | 1.17 = √(1 + 2 · 0.182) | as above |
| Factor C | 0.7 | as above |
The results are shown in the design check details in the chapter "Limiting slenderness according to 5.8.3.1(1)":
| Quantity | About y-axis | About z-axis |
| Slenderness λ | 9.54 | 10.73 |
| Limiting slenderness λlim | 10.81 | 10.81 |
| λ < λlim | fulfilled | fulfilled |
| Eccentricity due to imperfection ei | 3.1 mm | 3.1 mm |
| First-order moment M0Ed | 0 | 0 |
Without creep (φef = 0), RFEM 6 would determine A = 1.0; the user-defined value A = 0.7 corresponds to the recommended value of the manual calculation and is on the safe side. Since λ < λlim, RFEM 6 does not apply a second-order moment. The minimum eccentricity e0 = max(h/30; 20 mm) = 20 mm according to EN 1992-1-1, 6.1(4) is governing, which the stability analysis always takes into account – regardless of the option "Consider minimum eccentricity".
My,Ed = Mz,Ed = 3,376.5 kN · 0.02 m = 67.53 kNm As,req = 23.43 cm2
Utilization
η = 1.11 [-] Since η > 1.0, the design with 4 Ø 20 is not fulfilled.
Important: Calculation procedure 1 corresponds to the design according to the standard. For the constructed column, more reinforcement is required than the 4 Ø 20 from the manual calculation (As,req = 23.43 cm2). The manual calculation considers the idealized case without eccentricity.
Calculation procedure 2 – Design as in the manual calculation
Calculation procedure 2 replicates the pure axial compression of the manual calculation: RFEM 6 returns As,req = 9.41 cm2 and a utilization of 0.964.
| Setting | Value | Location in RFEM 6 |
| Consider minimum eccentricity | Deactivated | Ultimate configuration, tab "Members" |
| Perform stability analysis with equivalent member method | Deactivated | Ultimate configuration |
Both options must be deactivated. If only the first one is deactivated, e0 remains in the stability analysis (result as in calculation procedure 1). Without the equivalent member method, RFEM 6 does not output λ and λlim; these values come from calculation procedure 1.
Check
NRd = 0.18 m2 · 16.67 MN/m2 + 12.57 cm2 · 40.0 kN/cm2 = 3,503 kN
Utilization
η = NEd / NRd = 3,376.5 kN / 3,503 kN = 0.964 [-] Since η < 1.0, the design for pure compression is fulfilled.
The design check details show the state under NEd (σc = −16.35 N/mm2, σs = −344.9 N/mm2 at ε ≈ −1.72 ‰), not the failure state at εc2 = −2.0 ‰.
Comparison of results
Calculation procedure 2 matches the manual calculation. Calculation procedure 1 shows that 4 Ø 20 is not sufficient for a design according to the standard with minimum eccentricity.
| Quantity | Manual calculation | Calculation procedure 1 (with e0) | Calculation procedure 2 (without e0) |
| NEd | −3,376.5 kN | −3,376.5 kN | −3,376.5 kN |
| My,Ed / Mz,Ed | 0 | 67.53 / 67.53 kNm | 0 / 0 |
| Slenderness λz | 10.73 | 10.73 | – |
| Limiting slenderness λlim | 10.81 | 10.81 | – |
| Required longitudinal reinforcement As,req | 9.41 cm2 | 23.43 cm2 | 9.41 cm2 |
| Provided longitudinal reinforcement As,prov | 12.57 cm2 (4 Ø 20) | 12.57 cm2 (4 Ø 20) | 12.57 cm2 (4 Ø 20) |
| Cross-section utilization η | 0.96 | 1.11 | 0.964 |
Small deviations from the manual calculation result from rounding.
Conclusion
The manual calculation for pure axial compression is well suited for the preliminary design of the cross-section and for understanding the interaction of concrete and reinforcement. RFEM 6 replicates it exactly (As,req = 9.41 cm2) when minimum eccentricity and the equivalent member method are deactivated. The slenderness check also matches: λz = 10.73 < λlim = 10.81, second-order effects may be neglected.
However, for the design of a real column, pure compression is not sufficient. EN 1992-1-1 requires, according to 6.1(4), at least the eccentricity e0 = 20 mm, which RFEM 6 takes into account by default. This increases the required reinforcement to 23.43 cm2, and the 4 Ø 20 from the manual calculation are insufficient. In practice, therefore, minimum eccentricity and the equivalent member method should always remain activated.