Design of five types of seismic force-resisting systems (SFRS) includes Special Moment Frame (SMF), Intermediate Moment Frame (IMF), Ordinary Moment Frame (OMF), Ordinary Concentrically Braced Frame (OCBF), and Special Concentrically Braced Frame (SCBF)
Ductility check of the width-to thickness ratios for webs and flanges
Calculation of the required strength and stiffness for stability bracing of beams
Calculation of the maximum spacing for stability bracing of beams
Calculation of the required strength at hinge locations for stability bracing of beams
Calculation of the column required strength with the option to neglect all bending moments, shear, and torsion for overstrength limit state
Design check of column and brace slenderness ratios
For calculation diagrams, the "2D | Hinge" is available. These hinge diagrams show the hinge response of load situations for nonlinear hinges.
For calculations with several load situations, such as is the case with pushover analyzes and time history analysis, you can evaluate the state of the hinge in each load step.
In the Steel Joints add-on, you can classify the joint stiffness.
In addition to the initial stiffness, the table also shows the limit values for hinged and rigid connections for the selected internal forces N, My, and/or Mz. The resulting classification is then displayed in tables as "hinged", "semi-rigid", or "rigid".
Consideration of nonlinear component behavior using plastic standard hinges for steel (FEMA 356, EN 1998‑3) and nonlinear material behavior (masonry, steel - bilinear, user-defined working curves)
Direct import of masses from load cases or combinations for the application of constant vertical loads
User-defined specifications for the consideration of horizontal loads (standardized to a mode shape or uniformly distributed over the height of the masses)
Determination of a pushover curve with selectable limit criterion of the calculation (a collapse or limit deformation)
Transformation of the pushover curve into the capacity spectrum (ADRS format, single degree of freedom system)
Bilinearization of the capacity spectrum according to EN 1998‑1:2010 + A1:2013
Transformation of the applied response spectrum into the required spectrum (ADRS format)
Determination of target displacement according to EC 8 (the N2 method according to Fajfar 2000)
Graphical comparison of the capacity and required spectrum
Graphical evaluation of the acceptance criteria of predefined plastic hinges
Result display of the values used in the iterative calculation of the target displacement
Access to all results of the structural analysis in the individual load levels
What are plastic hinges? Very simple – plastic hinges according to FEMA 356 help you to create pushover curves. These are nonlinear hinges with preset yield properties and acceptance criteria for steel members (Chapter 5 of FEMA 356).
The results for members can be displayed graphically, using the Member Hinges navigator category. The numerical results of member hinges can be found in the Results by Member table category. The Member Hinge Deformations and Member Hinge Forces tables are available for the analysis and documentation of the deformation and force results in the area of member hinges.
The table lists the deformations and forces of each member for the locations specified in the Results Table Manager. There, you can also control which extreme values are displayed.
Did you know? You can easily define structural modifications in load cases of the Modal Analysis type. This allows you, for example, to individually adjust the stiffnesses of materials, cross-sections, members, surfaces, hinges, and supports. You can also modify stiffnesses for some design add-ons. Once you select the objects, their stiffness properties are adapted to the object type. In this way, you can define them in separate tabs.
Do you want to analyze the failure of an object (for example, a column) in the modal analysis? This is also possible without any problems. Simply switch to the Structure Modification window and deactivate the relevant objects.
RFEM allows you to use a special line hinge to model the special properties of the connection between the reinforced concrete slab and masonry wall. This limits the transferable forces of the connection depending on the specified geometry. You guess right: This means that the material cannot be overloaded.
The program develops interaction diagrams that are applied automatically. They represent the various geometric situations and you can use them to determine the correct stiffness.
Compared to the RF‑/STAGES add-on module (RFEM 5), the following new features have been added to the Construction Stages Analysis (CSA) add-on for RFEM 6:
Consideration of construction stages at RFEM level
Integration of the construction stage analysis into the combinatorics in RFEM
Additional structural elements, such as line hinges, are supported
Analysis of alternative construction processes in a model
Stress determination using an elastic-plastic material model
Design of masonry disc structures for compression and shear on the building model or single model
Automatic determination of stiffness of a wall-slab hinge
An extensive material database for almost all stone-mortar combinations available on the Austrian market (the product range is continuously being expanded, for other countries as well)
Automatic determination of material values according to Eurocode 6 (ÖN EN 1996‑X)
Simple definition of construction stages in the RFEM structure including visualization
Adding, removing, modifying, and reactivating member, surface, and solid elements and their properties (for example, member and line hinges, degrees of freedom for supports, and so on)
Automatic and manual combinatorics with load combinations in the individual construction stages (for example, to consider mounting loads, mounting cranes, and other loads)
Consideration of nonlinear effects such as tension member failure or nonlinear supports
Do not lose track of stiffnesses and initial deformations. In the individual load cases or combinations, you have the option to modify the stiffnesses of materials, cross-sections, nodal, line and surface supports, and member and line hinges for all or selected members. You can also consider initial deformations from other load cases or load combinations.
RFEM offers the following tables to display forces and deformations of hinges and releases:
4.45 Line Hinges - Deformations
4.46 Line Hinges - Forces
4.47 Member Hinges - Deformations
4.48 Member Hinges - Forces
4.49 Nodal Releases - Deformations
4.50 Nodal Releases - Forces
4.51 Line Releases - Deformations
4.52 Line Releases - Forces
The tables can be displayed in the prinout report. Moreover, the results in line hinges and line releases can be displayed graphically. It can be controlled by Project Navigator - Results.
Beam to Column joint category: connection possible as joint of the beam to the column flange as well as joint of the column to the girder flange
Beam to Beam joint category: design of beam joints as both moment-resisting end plate connections and rigid splice connections possible
Automatic export of model and load data possible from RFEM or RSTAB
Bolt sizes from M12 to M36 with strength grades 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, and 10.9 as long as the strength grades are available in the selected National Annex
Almost any bolt spacing and edge distances (a check of the allowable distances is performed)
Beam strengthening with tapers or stiffeners on the top and bottom surfaces
End plate connection with and without overlap
Connection with pure bending stress, pure normal force load (tension joint), or combination of normal force and bending possible
Calculation of connection stiffnesses and check if a hinged, semi-rigid, or rigid connection exists
End plate connection in a beam-column setup
Joint beams or columns can be stiffened with tapers on one side or with stiffeners to one or both sides
Wide range of possible stiffeners of the connection (for example, complete or incomplete web stiffeners)
Up to ten horizontal and four vertical bolts possible
Connected object possible as constant or tapered I-section
Designs:
Ultimate limit state of the connected beam (such as shear or tension resistance of the web plate)
Ultimate limit state of the end plate at the beam (for example, T-stub under tensile stress)
Ultimate limit state of the welds at the end plate
Ultimate limit state of the column in the area of the connection (for example, column flange under bending – T-stub)
All designs are performed according to EN 1993-1-8 and EN 1993-1-1
Moment-resisting end plate joint
Two or four vertical and up to 10 horizontal bolt rows
Joint beams can be stiffened with tapers on one side or with stiffeners to one or both sides
Connected objects are possible as constant or tapered I-sections
Designs:
Ultimate limit state of the connected beams (such as shear or tension resistance of the web plates)
Ultimate limit state of the end plates at the beam (for example, T-stub under tensile stress)
Ultimate limit state of the welds at the end plates
Ultimate limit state of the bolts in the end plate (combination of tension and shear)
Rigid splice plate connection
For the flange plate connection, up to ten bolt rows one behind the other possible
For the web plate connection, up to ten bolt rows possible each in vertical and horizontal directions
Material of the cleat can be different from the one of the beams
Designs:
Ultimate limit state of the joint beams (for example, net cross-section in the tension area)
Ultimate limit state of the cleat plates (for example, net cross-section under tensile stress)
Ultimate limit state of the single bolts and the bolt groups (for example, shear resistance design of the single bolt)
The member hinge nonlinearities "Scaffolding - N phiy / phiz" and "Scaffolding Diagram" enable the mechanical simulation of a tube joint with an inner stub between two member elements.
The equivalent model transfers the bending moment via the overpressed outer pipe and after positive locking additionally via the inner stub, depending on the compression state at the member end.
All roof shapes allow for a free selection of stiffening diagonals. The following types are available:
Falling diagonals
Rising diagonals
Crossing diagonals with verticals
Crossing diagonals without verticals
Crossing diagonals with steel strips (ties)
Consideration of window rows in the ridge by selecting an inner intermediate part.
For design according to EC 5 (EN 1995), the following National Annexes are available:
DIN EN 1995-1-1/NA:2013-08 (Germany)
NBN EN 1995-1-1/ANB:2012-07 (Belgium)
DK EN 1995-1-1/NA:2011-12 (Denmark)
SFS EN 1995-1-1/NA:2007-11 (Finland)
NF EN 1995-1-1/NA:2010-05 (France)
UNI EN 1995-1-1/NA:2010-09 (Italy)
NEN EN 1995-1-1/NB:2007-11 (Netherlands)
ÖNORM B 1995-1-1:2015-06 (Austria)
PN EN 1995-1-1/NA:2010-09 (Poland)
SS EN 1995-1-1 (Sweden)
STN EN 1995-1-1/NA:2008-12 (Slovakia)
SIST EN 1995-1-1/A101:2006-03 (Slovenia)
CSN EN 1995-1-1:2007-09 (Czech Republic)
BS EN 1995-1-1/NA:2009-10 (the United Kingdom)
Simple geometry input with illustrative graphics
Automatic generation of wind loads
Automatic creation of required combinations for the ultimate and serviceability limit states, as well as fire resistance design
Free definition of the load cases to be used
Extensive material library
Optional extension of material library by further materials
Extensive library of permanent loads
Allocation of framework to service classes and specification of service class categories
Determination of design ratios, support forces, and deformations
Info icon indicating successful or failed design
Color reference scales in result tables
Direct data export to MS Excel
DXF interface for preparation production documents in CAD
Program languages: English, German, Czech, Italian, Spanish, French, Portuguese, Polish, Chinese, Dutch, and Russian
Verifiable printout report, including all required designs. Printout report available in many output languages; for example, English, German, French, Italian, Spanish, Russian, Czech, Polish, Portuguese, Chinese, and Dutch.
In the ultimate limit state design, the stiffness of the hinge is divided by the partial safety factor and in the serviceability limit state design calculated using the mean stiffnesses. The limit values for the ultimate and the serviceability limit states can be defined separately.
Hinged girder system (Gerber beams) with and without cantilevers
Automatic generation of wind and snow loads
Automatic creation of required combinations for the ultimate and serviceability limit states, as well as fire resistance design
For design according to EC 5 (EN 1995), the following National Annexes are available:
DIN EN 1995-1-1/NA:2013-08 (Germany)
NBN EN 1995-1-1/ANB:2012-07 (Belgium)
DK EN 1995-1-1/NA:2011-12 (Denmark)
SFS EN 1995-1-1/NA:2007-11 (Finland)
NF EN 1995-1-1/NA:2010-05 (France)
UNI EN 1995-1-1/NA:2010-09 (Italy)
NEN EN 1995-1-1/NB:2007-11 (Netherlands)
ÖNORM B 1995-1-1:2015-06 (Austria)
PN EN 1995-1-1/NA:2010-09 (Poland)
SS EN 1995-1-1 (Sweden)
STN EN 1995-1-1/NA:2008-12 (Slovakia)
SIST EN 1995-1-1/A101:2006-03 (Slovenia)
CSN EN 1995-1-1:2007-09 (Czech Republic)
BS EN 1995-1-1/NA:2009-10 (the United Kingdom)
Consideration of optimization options by user specifications according to the respective standard:
Shear force reduction of single loads near support
Shear force reduction of load introduction at the cross-section top point
Moment redistribution in support zone
Reduction of torsional stress by means of user-defined entry of moment
Increase of bending stiffnesses for flat-ended or edgewise bending strains
Simple geometry input with illustrative graphics
Extensive material library for both standards
Optional extension of material library by further materials
Extensive library of permanent loads
Allocation of framework to service classes and specification of service class categories
Determination of design ratios, support forces, and deformations
Info icon indicating successful or failed design
Color reference scales in result tables
Direct data export to MS Excel
Program languages: English, German, Czech, Italian, Spanish, French, Portuguese, Polish, Chinese, Dutch, and Russian
Verifiable printout report, including all required designs. Printout report available in many output languages; for example, English, German, French, Italian, Spanish, Russian, Czech, Polish, Portuguese, Chinese, and Dutch.
Direct import of stp files from various CAD programs
Hinged column, optionally with elastic restraint of head or footing
Bracket, optionally with elastic restraint of footing
Simple geometry input with illustrative graphics
Extensive material library
Allocation of framework to service classes and specification of service class categories
Detailed settings of the fire resistance design
Specification of limit deformation for the serviceability limit state design
Determination of design ratios, support forces, and deformations
For design according to EC 5 (EN 1995), the following National Annexes are available:
DIN EN 1995-1-1/NA:2013-08 (Germany)
NBN EN 1995-1-1/ANB:2012-07 (Belgium)
DK EN 1995-1-1/NA:2011-12 (Denmark)
SFS EN 1995-1-1/NA:2007-11 (Finland)
NF EN 1995-1-1/NA:2010-05 (France)
UNI EN 1995-1-1/NA:2010-09 (Italy)
NEN EN 1995-1-1/NB:2007-11 (Netherlands)
ÖNORM B 1995-1-1:2015-06 (Austria)
PN EN 1995-1-1/NA:2010-09 (Poland)
SS EN 1995-1-1 (Sweden)
STN EN 1995-1-1/NA:2008-12 (Slovakia)
SIST EN 1995-1-1/A101:2006-03 (Slovenia)
CSN EN 1995-1-1:2007-09 (Czech Republic)
BS EN 1995-1-1/NA:2009-10 (the United Kingdom)
Automatic generation of wind and snow loads
Multiple optional reductions according to the selected standard
Direct data export to MS Excel
Program languages: English, German, Czech, Italian, Spanish, French, Portuguese, Polish, Chinese, Dutch, and Russian
Verifiable printout report, including all required designs. Printout report available in many output languages; for example, English, German, French, Italian, Spanish, Russian, Czech, Polish, Portuguese, Chinese, and Dutch.
Direct import of stp files from various CAD programs
Hinged girder system (Gerber beams) with and without cantilevers
For design according to EC 5 (EN 1995), the following National Annexes are available:
DIN EN 1995-1-1/NA:2013-08 (Germany)
NBN EN 1995-1-1/ANB:2012-07 (Belgium)
DK EN 1995-1-1/NA:2011-12 (Denmark)
SFS EN 1995-1-1/NA:2007-11 (Finland)
NF EN 1995-1-1/NA:2010-05 (France)
UNI EN 1995-1-1/NA:2010-09 (Italy)
NEN EN 1995-1-1/NB:2007-11 (Netherlands)
ÖNORM B 1995-1-1:2015-06 (Austria)
PN EN 1995-1-1/NA:2010-09 (Poland)
SS EN 1995-1-1 (Sweden)
STN EN 1995-1-1/NA:2008-12 (Slovakia)
SIST EN 1995-1-1/A101:2006-03 (Slovenia)
CSN EN 1995-1-1:2007-09 (Czech Republic)
BS EN 1995-1-1/NA:2009-10 (the United Kingdom)
Automatic generation of wind and snow loads
Multiple optional reductions according to the selected standard
Simple geometry input with illustrative graphics
Free entry of tapered geometries. Free selection of the grain angle allows for user-defined design of the compressive and tensile areas for bending
Comprehensive and extensible material library
Determination of design ratios, support forces, and deformations
Color reference scales in result tables
Direct data export to MS Excel
DXF interface for preparation production documents in CAD
Program languages: English, German, Czech, Italian, Spanish, French, Portuguese, Polish, Chinese, Dutch, and Russian
Verifiable printout report, including all required designs. Printout report available in many output languages; for example, English, German, French, Italian, Spanish, Russian, Czech, Polish, Portuguese, Chinese, and Dutch.
Direct import of stp files from various CAD programs
Always keep track of things by assigning different colors to the various objects in your structure. Thus, the rendering display of the structure is even clearer; and you can see the essentials at a glance.
You can distinguish between Materials, Cross-Sections, Member Types, Member Hinges, Surface Types - Geometry, Surface Types - Stiffness, Surface Thicknesses, Solid Types, Surface Sides, Named Visibilities, and Effective Length Factors.
The RX- TIMBER Continuous Beam program is suitable for the design of single-span and continuous beams as well as hinged girder systems (Gerber) with or without cantilevers.
Definition of any additional support and free selection of degrees of freedom (additional free definition of translational and rotational spring stiffness of supports and hinges)
Arrangement of up to five collar/tie beams, including intermediate support for duopitch roof
Automatic generation of wind and snow loads
Automatic generation of required combinations for the ultimate and serviceability limit states, as well as fire resistance design (additional definition of several member and nodal loads)
For design according to EC 5 (EN 1995), the following National Annexes are available:
Germany DIN EN 1995-1-1/NA:2013-08 (Germany)
NBN EN 1995-1-1/ANB:2012-07 (Belgium)
BDS EN 1995-1-1/NA:2012-02 (Bulgaria)
DK EN 1995-1-1/NA:2011-12 (Denmark)
SFS EN 1995-1-1/NA:2007-11 (Finland)
NF EN 1995-1-1/NA:2010-05 (France)
I S. EN 1995-1-1/NA:2010-03 (Ireland)
UNI EN 1995-1-1/NA:2010-09 (Italy)
NEN EN 1995-1-1/NB:2007-11 (Netherlands)
ÖNORM B 1995-1-1:2015-06 (Austria)
PN EN 1995-1-1/NA:2010-09 (Poland)
SS EN 1995-1-1 (Sweden)
STN EN 1995-1-1/NA:2008-12 (Slovakia)
SIST EN 1995-1-1/A101:2006-03 (Slovenia)
CSN EN 1995-1-1:2007-09 (Czech Republic)
BS EN 1995-1-1/NA:2009-10 (the United Kingdom)
CYS EN 1995-1-1/NA:2011-02 (Cyprus)
Simple geometry input with illustrative graphics
Input of tapered cantilevers with cut-to-grain on the bottom side of rafters
Extensive material library that can be extended by user-defined materials
Determination of design ratios, support forces, and deformations
Color reference scales in result tables
Direct data export to MS Excel
Program languages: English, German, Czech, Italian, Spanish, French, Portuguese, Polish, Chinese, Dutch, and Russian
Verifiable printout report, including all required designs. Printout report available in many output languages; for example, English, German, French, Italian, Spanish, Russian, Czech, Polish, Portuguese, Chinese, and Dutch.
In the individual load cases or combinations, there is the option to modify the stiffnesses of materials; cross-sections; nodal, line and surface supports; and member and line hinges for all or selected members. Furthermore, it is possible to consider initial deformations from other load cases or load combinations.
Geometry, material, cross-section, action, and imperfection data are entered in clearly arranged input windows:
Geometry
Quick and convenient data input
Definition of support conditions based on various support types (hinged, hinged movable, rigid, and user-defined, as well as lateral on upper or bottom flange)
Optional specification of warping restraint
Variable arrangement of rigid and deformable support stiffeners
Possibility to insert hinges
CRANEWAY Cross-Sections
I-shaped rolled cross-sections (I, IPE, IPEa, IPEo, IPEv, HE-B, HE-A, HE-AA, HL, HE-M, HE, HD, HP, IPB-S, IPB-SB, W, UB, UC, and other cross-sections according to AISC, ARBED, British Steel, Gost, TU, JIS, YB, GB, and others) combinable with section stiffener on the upper flange (angles or channels) as well as rail (SA, SF) or splice with user-defined dimensions
Unsymmetrical I-sections (type IU) also combinable with stiffeners on the upper flange as well as with rail or splice
Actions
It is possible to consider the actions of up to three simultaneously operated cranes. You can simply select a standard crane from the library. You can also enter data manually:
Number of cranes and crane axles (maximum of 20 axles per crane), center distances, position of crane buffers
Classification in damage classes with editable dynamic factors according to EN 1993-6, and in lifting classes and exposure categories according to DIN 4132
Vertical and horizontal wheel loads from self-weight, hoist load, mass forces from drive, as well as loads from skewing
Axial loading in driving direction as well as buffer forces with user-defined eccentricities
Permanent and variable secondary loads with user-defined eccentricities
Imperfections
The imperfection load applies in compliance with the first natural vibration mode - either identically for all load combinations to be designed, or individually for each load combination, as mode shapes may vary depending on the load.
Convenient tools available for scaling the mode shapes (rise determination of inclination and precamber).
RX- TIMBER Column designs hinged columns (optionally with elastic head or footing restraint) and brackets (optionally with elastic foundation of the footing column).
For this, circular and rectangular cross‑sections are available in the program.
Comprehensive and easy options in the individual input windows facilitate the representation of the structural system:
Nodal Supports
The support type of each node is editable.
It is possible to define a warp stiffening on each node. The resulting warp spring is determined automatically using the input parameters.
Elastic member foundation
In the case of elastic member foundations, you can manually enter spring constants.
Alternatively, you can use the various options to define the rotational and translational springs from a shear panel.
Member End Springs
RF-/FE-LTB calculates the individual spring constants automatically. You can use the dialog boxes and detailed pictures to represent a translational spring by connecting component, a rotational spring by a connecting column, or a warping stiffener (available types: end plate, channel section, angle, connecting column, cantilevered portion).
Member Hinges
If there are no member hinges defined in RFEM/RSTAB for the set of members, you can define them directly in the RF-/FE-LTB add-on module.
Load Data
The nodal and member loads of the selected load cases and combinations are displayed in separate windows. There you can edit, delete, or add them individually.
Imperfections
RF-/FE-LTB automatically applies the imperfections by scaling the lowest eigenvector.