Steel cantilever beam with connection to foundation plate. With RF-/FOUNDATION-PRO, you can check the allowable eccentricity of the soil pressure resultant according to DIN EN 1997-1/NA. The design is carried out using characteristic or representative stresses. In addition, aspects of the support, the foundation, the geotechnical engineering, as well as rotations, foundation rotations, joints, and eccentricities are taken into account.
Steel Cantilever Beam with Foundation Connection
| Number of Nodes | 2 |
| Number of Members | 1 |
| Number of Load Cases | 4 |
| Number of Load Combinations | 34 |
| Number of Result Combinations | 4 |
| Total Weight | 0,202 t |
| Dimensions (Metric) | 0.500 x 0.500 x 4.250 m |
| Dimensions (Imperial) | 1.64 x 1.64 x 13.94 feet |
| Program Version | 8.24.02 |
You can download this structural model to use it for training purposes or for your projects. However, we do not assume any guarantee or liability for the accuracy or completeness of the model.