Adrian Langhammer General RFEM RF-CONCRETE RF-TENDON Design

How can the fatigue analysis for reinforced concrete and prestressed concrete be carried out in RFEM? I found a result combination of type fatigue, but can not find the proof in the modules.

Answer

The proof is currently not implemented in the RF-BETON modules. In RF-CONCRETE Members or Surfaces, the input parameters for the verification, such as the reinforcing steel stress, can be determined. The proof itself must currently be kept outside the program.

In the external add-on module RF-TENDON Design the proof according to EN 1992-1-1 6.8.5 is implemented. For this, the result combination of the type fatigue is to be used.

Keywords

Reinforced concrete Prestressed concrete Fatigue Fatigue check Damage equivalent vibration ranges Damage-equivalent stress range

Contact us

Contact to Dlubal

Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.