Question

Where can I display steel stresses for the design of a surface in RF‑CONCRETE?


Answer:

In RF‑CONCRETE Surfaces, you can use the [Info] button to display the corresponding steel stresses for each design location for the ultimate limit state (see Image 01). A graphical display is not possible here.

In the serviceability limit state design, it is possible to display the steel stress graphically, since a corresponding design can be performed (see Image 02).