Wieland Götzler Add-on Modules STEEL EC3 RF-STEEL EC3

I have activated in the module RF- / STEEL EC3 Gamma M1 for calculating the cross-section capacity because I want to cover stability proofs with theory II. Order and imperfections, but the cross-sectional verification for my design in Germany is 1.0, why?

Answer

Probably the correct national annex is not selected in the basic information of the module. For example, if the rating is "CEN" then the recommendations of the standard will be used, setting Gamma M1 at 1.0. Please select the correct national annex.

Keywords

Steel construction Stability EC3 Gamma M1 Partial safety factor Cross-section bearing capacity Stability proofs Second order theory