New
FAQ 002811 EN-US 04/05/2019

Daniel Dlubal Results RFEM

Why are not all voltages displayed in the Results Navigator? Even with the internal forces not all options are shown.

Answer

This depends on the choice of model type. In this case a flat system was chosen. Thus, only for this level, the relevant results are displayed because they are reduced because of the limited coordinates and degrees of freedom. If, on the other hand, a 3D system is selected as the model type, all stresses and internal forces are displayed.

Keywords

Result Navigator Model type Display voltages Display of internal forces