FAQ 002022 EN

Add-on Modules RF-FRAME-JOINT Pro FRAME-JOINT Pro 5.xx 8.xx

Why there is no option for inclined headplate available?

Answer

The following should be take into account to arrange the end plate of a column in an inclined position:

  • The beam located to the left and to the right of the column should have no member eccentricity.
  • The beam inclination to the left and to the right of the column has to be identical.