Answer:
This is possible with the RF‑CONCRETE Surfaces add-on module. To do this, select a loading for the Serviceability Limit State in Window 1.1 General Data of the RF‑CONCRETE Surfaces add-on module. Then, you can define the specifications for determining the Minimum Reinforcement for Effects Due to Restraints in the Limit of Crack Width tab of Window 1.3 Surfaces.