662x
003358
2019-07-30

Results: Extreme Values of Support Forces with Filter

For my result evaluation, the extreme values of the vertical support forces with the corresponding horizontal forces from a result combination are required for several support nodes. Is it possible to set this in the program?


Answer:

The graphical result display always shows the extreme values of all support reactions. That is, the largest and the smallest values across all combination possibilities. The individual support forces cannot be combined in this way, as they usually occur in different load situations.

However, the extreme values with the corresponding results are displayed in result tables. Furthermore, Column H shows the corresponding load combination or the corresponding load cases by default.

If you only need to display the extreme values of PZ with the corresponding horizontal forces, you can use the filter function of the result table, as shown in the image.


Author

Mr. Fröhlich provides technical support to our customers and is responsible for development in the area of reinforced concrete structures.



;