In the Geotechnical Analysis add-on, the member of the type 'Pile' is available. Pile resistance types are created for the pile. It defines the parameters for the resistance from skin friction and the pile end pressure.
The pile is then embedded in the adjacent soil solid under consideration of the resistance characteristics resulting from the parameters of the skin friction and the peak pressure.
The "Results by Story" table of a building model shows the center of gravity for load cases and load combinations. In addition to the self-weight, the vertical loads of the respective load cases and load combinations are also taken into account.
You can also use the "Center of Gravity and Information About Selected Objects" dialog box to display the center of gravity, taking into account the selected loading.
In the Geotechnical Analysis add-on, the high-quality material model "Modified Hardening Soil Model" is available. This material model is suitable for a variety of soils and is able to appropriately represent the following properties of the real soil.
Stress dependence of soil stiffness
Load path dependence of soil stiffness
Plastic strains even before reaching the limit condition
Increasing shear resistance with increasing mesh refinement
Increasing yield strength with increasing stress until reaching the limit yield condition
Failure criterion according to Mohr-Coulomb
You can find more information about this material model and the definition of the input in RFEM in the corresponding chapter of the online manual for the Geotechnical Analysis add-on.
When modeling stories, you can use the "Semi-Rigid Diaphragm" option for slabs.
In principle, this modeling option selects the same approach as for the "Rigid Diaphragm" modeling of stories. In contrast to the rigid diaphragm, no nodal coupling is carried out from the center of gravity to each FE node. This way, it is possible to take into account the flexibility of the slab.
You can neglect openings with a certain area in the building model calculation. This function can be activated in the global settings of the building stories. A warning message appears saying that the openings have been neglected.