FAQ 003623 EN
12 November 2019
003623
Where in RF‑PUNCH Pro is the direction of the individual reinforcement layers displayed?
Answer
Keywords
Punching shear Punching Reinforcement Direction Reinforcement position Position Orientation Width of reinforcement Longitudinal reinforcement
Downloads
Contact us
Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.
Recommended Events
Timber Beam and Surface Structures | Part 1: Modeling, Load Input, Combinatorics
Webinar 4 May 2021 2:00 PM - 3:00 PM CEST
Eurocode 3 | Steel structures according to DIN EN 1993-1-1
Online Training 6 May 2021 8:30 AM - 12:30 PM CEST
Eurocode 2 | Concrete structures according to DIN EN 1992-1-1
Online Training 12 May 2021 8:30 AM - 12:30 PM CEST
Eurocode 5 | Timber structures according to DIN EN 1995-1-1
Online Training 20 May 2021 8:30 AM - 12:30 PM CEST
RFEM | Structural dynamics and earthquake design according to EC 8
Online Training 2 June 2021 8:30 AM - 12:30 PM CEST
Stability Design in Steel Construction with RFEM and RSTAB
Webinar 1 December 2020 2:00 PM - 2:45 PM CET
Videos

KB 001618 | Punching Shear Design in RF-PUNCH Pro Taking Into Account Enlarged Column Head
Length 1:45 min

RFEM 5 Tutorial for Students | 015 Dynamics: Response Spectrum Analysis | Input Data
Length 9:17 min

KB 000748 | Designing Surfaces Using Internal Forces Without Rib Component in RF-CONCRETE Surfaces
Length 0:50 min
Models to Download
Knowledge Base Articles

Dealing with Singularities When Determining Loads in RF-PUNCH Pro
In RF-PUNCH Pro, you have different options to determine the punching loads on wall corners and wall ends on the basis of the RFEM surface internal forces.
Screenshots
Product Features Articles

Material Model Orthotropic Masonry 2D
The material model Orthotropic Masonry 2D is an elastoplastic model that additionally allows softening of the material, which can be different in the local x- and y-direction of a surface. The material model is suitable for (unreinforced) masonry walls with in-plane loads.
Frequently Asked Questions (FAQ)
- When should the punching load be determined with the (un)smoothed distribution of the shear forces at the critical perimeter?
- I would like to perform the punching shear design on a column with connected downstand beams as a wall corner or Perform wall end. However, the module applies an internal column. Is it possible to adjust it?
- What is the meaning of "Common Surfaces" in RF‑PUNCH Pro? Do I have to set anything here?
- The critical perimeter at the wall corner in my structure looks strange. What can be the reason?
- Can I design a reinforced concrete structure according to ÖNORM in RFEM?
- I have entered a line support with "Wall in Z," but I cannot select the wall end for the design in RF‑PUNCH Pro. Why?
- Which static depth d is applied in RF‑PUNCH Pro for the design on surfaces with a variable thickness?
- Are the minimum moments also considered in the case of punching shear on foundation plates?
- How can I display the results from RF‑PUNCH Pro exactly in the critical perimeter with a result value?
- What is the meaning of a "main load" and "secondary load" in RF‑PUNCH Pro and where does this load come from?
Customer Projects