The "Results by Story" table of a building model shows the center of gravity for load cases and load combinations. In addition to the self-weight, the vertical loads of the respective load cases and load combinations are also taken into account.
You can also use the "Center of Gravity and Information About Selected Objects" dialog box to display the center of gravity, taking into account the selected loading.
When modeling stories, you can use the "Semi-Rigid Diaphragm" option for slabs.
In principle, this modeling option selects the same approach as for the "Rigid Diaphragm" modeling of stories. In contrast to the rigid diaphragm, no nodal coupling is carried out from the center of gravity to each FE node. This way, it is possible to take into account the flexibility of the slab.
You can neglect openings with a certain area in the building model calculation. This function can be activated in the global settings of the building stories. A warning message appears saying that the openings have been neglected.
Global 3D calculation of the global model, where the slabs are modeled as a rigid plane (diaphragm) or as a bending plate
Local 2D calculation of the individual floors
After the calculation, the results of the columns and walls from the 3D calculation and the results of the slabs from the 2D calculation are combined in a single model. This means that there is no need to switch between the 3D model and the individual 2D models of the slabs. The user only works with one model, saves valuable time, and avoids possible errors in the manual data exchange between the 3D model and the individual 2D ceiling models.
The vertical surfaces in the model can be divided into shear walls and opening lintels. The program automatically generates internal result members from these wall objects, so they can be designed as members according to any standard in the Concrete Design add-on.
You have the option to perform the fire resistance design of surfaces using the reduced cross-section method. The reduction is applied over the surface thickness. It is possible to perform the design checks for all timber materials allowed for the design.
For cross-laminated timber, depending on the type of adhesive, you can select whether it is possible for individual carbonized layer parts to fall off, and whether you can expect increased charring in certain layer areas.