14 Results
View Results:
Sort by:
Cutting and Editing Plates when Modeling Steel Joints
Why is it not possible to select the plate I want to cut/edit in the Plate Editor / Plate Cut?
Different Stresses in Static Analysis and Stress-Strain Analysis
Why are the stresses of the structural analysis different from those calculated with the Stress-Strain Analysis add-on?
Load Extension Isotropic Masonry | Plastic
Is it possible to influence the transverse distribution of a load in the case of the Isotropic | Masonry | Plastic material model?
- 005437
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Steel Joints for RFEM 6
- Torsional Warping (7 DOF) for RFEM 6
- Torsional Warping (7 DOF) for RSTAB 9
- Steel Structures
- Structural Analysis & Design
- Stress Analysis
- Stability Analysis
- Warping Torsion Analysis
- Steel Connections
- Cold-Formed Sections
- Eurocode 3
- ANSI/AISC 360
- CSA S16
- IS 800
- GB 50017
- SP 63.13330
- BS 5950-1
- AS 4100
- SIA 263
Programs for Steel Structures
Which programs and add-ons are suitable for the structural analysis and design of steel structures?
Instability when Using Building Model with "Rigid Diaphragm"
I have a 3D model and try to split it up into "walls" and "surfaces" with the Building Model and to calculate them separately. However, my structural system becomes unstable then. What can be the reason?
Splice Connection
How do I create a splice connection in the Steel Joints add-on?
AISC 360-16 Shear Plane in Thread Option
Can I exclude bolt threads from the shear planes according to AISC 360-16 in the Steel Joints Add-on?
Surface Type Error
I received an error message “Surface of incompatible type... (Surface in upper plane of building story must be of ‘Load transfer’ type)” when running the calculation. What is the reason?
Case-Related Design with Different Load Situations
How can I carry out case-related design for different load situations?
Stress Ratio
The limit stress is activated, but my stress ratio is “non-designable” in the Stress-Strain Analysis add-on. What could be the reason?
Construction Stages - Modifying Properties
Is it possible to change the properties of members or surfaces, such as their location, in the individual construction stages?
Line Hinge of Slab-Wall Connection
I would like to connect my masonry wall to a reinforced concrete slab. What is the best way to create a line hinge?
Analyse de déformation
Is it possible to display the deformation analysis of a surface (limit 0.5‰)?
- 005113
- Timber Design for RFEM 6
- Timber Design for RSTAB 9
-
- Aluminum Design for RFEM 6
- Aluminum Design for RSTAB 9
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Stress-Strain Analysis for RFEM 6
- Stress-Strain Analysis for RSTAB 9
- Steel Joints for RFEM 6
- Timber Structures
- Concrete Structures
- Steel Structures
- Structural Analysis & Design
- Eurocode 2
- Eurocode 3
- Eurocode 5
- Eurocode 9