20 Results
View Results:
Sort by:
- 005113
- Timber Design for RFEM 6
- Timber Design for RSTAB 9
-
- Aluminum Design for RFEM 6
- Aluminum Design for RSTAB 9
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Stress-Strain Analysis for RFEM 6
- Stress-Strain Analysis for RSTAB 9
- Steel Joints for RFEM 6
- Timber Structures
- Concrete Structures
- Steel Structures
- Structural Analysis & Design
- Eurocode 2
- Eurocode 3
- Eurocode 5
- Eurocode 9
Materials of National Annexes
Where can I find the materials for the corresponding National Annexes in RFEM 6 and RSTAB 9?
Response Spectrum Analysis
How can I perform an earthquake analysis in RFEM 6 and RSTAB 9?
Neglecting Masses in RFEM 6 / RSTAB 9
How can I neglect masses in my modal analysis in RFEM 6 / RSTAB 9?
Analyse de déformation
Is it possible to display the deformation analysis of a surface (limit 0.5‰)?
Export of Response Spectrum
Can I export a response spectrum from RFEM 6 and use it in RFEM 5, for example?
Unstable Model - Troubleshooting
My model in RFEM 6 / RSTAB 9 is unstable. How can I fix it?
Instability
My model is unstable. What could be the reason?
Construction Stages - Modifying Properties
Is it possible to change the properties of members or surfaces, such as their location, in the individual construction stages?
Stress Ratio
The limit stress is activated, but my stress ratio is “non-designable” in the Stress-Strain Analysis add-on. What could be the reason?
Case-Related Design with Different Load Situations
How can I carry out case-related design for different load situations?
Creating Response Spectrum ASCE 7-22
How can I create a response spectrum according to ASCE 7‑22?
Surface Type Error
I received an error message “Surface of incompatible type... (Surface in upper plane of building story must be of ‘Load transfer’ type)” when running the calculation. What is the reason?
Instability
My model is unstable. What could be the reason?
AISC 360-16 Shear Plane in Thread Option
Can I exclude bolt threads from the shear planes according to AISC 360-16 in the Steel Joints Add-on?
Splice Connection
How do I create a splice connection in the Steel Joints add-on?
Instability when Using Building Model with "Rigid Diaphragm"
I have a 3D model and try to split it up into "walls" and "surfaces" with the Building Model and to calculate them separately. However, my structural system becomes unstable then. What can be the reason?
Stability Analysis with Incrementally Increasing Loading
Can I incrementally increase the load in RFEM 6 or RSTAB 9?
- 005437
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Steel Joints for RFEM 6
- Torsional Warping (7 DOF) for RFEM 6
- Torsional Warping (7 DOF) for RSTAB 9
- Steel Structures
- Structural Analysis & Design
- Stress Analysis
- Stability Analysis
- Warping Torsion Analysis
- Steel Connections
- Cold-Formed Sections
- Eurocode 3
- ANSI/AISC 360
- CSA S16
- IS 800
- GB 50017
- SP 63.13330
- BS 5950-1
- AS 4100
- SIA 263